Login
|
Login
Home
Design Guidelines
1.0 General
2.0 Private Development Projects
3.0 Agency Improvement Projects
4.0 Planning
5.0 Water Pipeline Design
6.0 Sewer Pipeline Design
7.0 Reservoir Design
8.0 Pressure/Flow Control Stations
9.0 Water Pump Station Design
10.0 Sewer Pump Station Design
11.0 Corrosion Control
12.0 Specialized Design
Standard Specifications
Introduction
General Requirements
Site Work
Concrete
Wood and Plastics
Finishes
Equipment
Special Construction
Mechanical
Standard Drawings
Standard Drawings - Water
Potable Water and Recycled Water Facilities
Air and Vacuum Valve Details
Blowoff Details
Cathodic Protection Details
Fire Hydrant and Fire Service Details
General Water Information Details
Miscellaneous Water Details
Pipeline Details
Backflow Prevention Details
Water Service Lateral Details
Thrust and Anchor Blocks and Pipe Restraint Details
Valve Details
Standard Drawings - Sewer
Sewer Facilities
Cleanout Details
Sewer Information
Manhole Details
Pipeline Details
Sewer Service Lateral Details
Approved Materials
Appendices
Home
Design Guidelines
- 1.0 General
- 2.0 Private Development Projects
- 3.0 Agency Improvement Projects
- 4.0 Planning
- 5.0 Water Pipeline Design
- 6.0 Sewer Pipeline Design
- 7.0 Reservoir Design
- 8.0 Pressure/Flow Control Stations
- 9.0 Water Pump Station Design
- 10.0 Sewer Pump Station Design
- 11.0 Corrosion Control
- 12.0 Specialized Design
Standard Specifications
- Introduction
- General Requirements
- Site Work
- Concrete
- Wood and Plastics
- Finishes
- Equipment
- Special Construction
- Mechanical
Standard Drawings
- Standard Drawings - Water
- - Potable Water and Recycled Water Facilities
- - Air and Vacuum Valve Details
- - Blowoff Details
- - Cathodic Protection Details
- - Fire Hydrant and Fire Service Details
- - General Water Information Details
- - Miscellaneous Water Details
- - Pipeline Details
- - Backflow Prevention Details
- - Water Service Lateral Details
- - Thrust and Anchor Blocks and Pipe Restraint Details
- - Valve Details
- Standard Drawings - Sewer
- - Sewer Facilities
- - Cleanout Details
- - Sewer Information
- - Manhole Details
- - Pipeline Details
- - Sewer Service Lateral Details
Approved Materials
Appendices
You are here:
Standard Drawings
>>
Standard Drawings - Water
Back
POTABLE WATER AND RECYCLED WATER FACILITIES
Standard Drawings Title Page
(08-23-2019)
Table of Contents
(11-13-2023)
Updated
AIR AND VACUUM VALVE DETAILS
WA-01
50mm (2") Manual Air Valve (11-03-2006)
WA-02
50mm (2") Automatic Combination Air Release and Air/Vacuum Valve Installations (11-03-2006)
WA-03
50mm (2") Air and Vacuum Valve Enclosure Locations (11-03-2006)
WA-04
100mm (4") Automatic Combination Air Release and Air/Vacuum Valve Installations
(12-16-2019)
WA-05
150mm (6") Automatic Combination Air Release and Air/Vacuum Valve Installations
(12-16-2019)
WA-06
100mm & 150mm (4" & 6") Air and Vacuum Valve Enclosure Locations (09-28-2009)
WA-07
50mm (2") Below Ground Manual Air Valve in 300mm (12") Can (11-23-2011)
WA-0
8
50mm (2") Automatic Combination Air Release/Vacuum Valve with Blowoff Valve Installation (11-12-2020)
BLOWOFF DETAILS
WB-01
50mm (2") Blowoff Installation (07-28-2014)
WB-02
100mm (4") Blowoff Installation (07-28-2014)
WB-03
150mm (6") Blowoff Installation (07-28-2014)
WB-04
Blowoff Installation from End of Mains and from Steel Mains (07-28-2014)
WB-05
Temporary 50mm (2") Blowoff Installation (07-28-2014)
WB-06
50mm (2") Blowoff Installation in 300mm (12") Can (07-28-2014)
CATHODIC PROTECTION DETAILS
WC-01
Exothermic Weld Detail (03-01-2001)
WC-02
Rubber-Ring Joint Bonding Detail for Metallic Pipelines (03-01-2001)
WC-03
Buried Mechanical Joint Bonding Detail for Metallic Pipelines (03-01-2001)
WC-04
Above Ground Insulating Flange (03-01-2001)
WC-05
Buried Insulating Flange Detail (03-01-2001)
WC-06
Buried Insulating Flange Test Station Wiring Diagram (07-30-2007)
WC-07
Buried Insulated Valve Detail (07-30-2007)
WC-08 Not Used
WC-09
Two Wire Test Station (03-01-2001)
WC-10
Casing Test Station (03-01-2001)
WC-11
Single Anode Installation Detail (09-28-2009)
WC-12
Prepackaged Magnesium Anode Detail (09-28-2009 )
WC-13
Anode Test Station Wiring Diagram (11-12-2020)
WC-14
Cathodic Test Station Box (08-03-2018)
WC-15
Reference Electrode Installation Detail (03-01-2001)
WC-16
Prepackaged Reference Electrode Detail (03-01-2001)
WC-17
New Installation of Sacrificial Anodes for Copper Tubing (12-31-2003)
WC-18
Retrofit Installation of Sacrificial Anodes for Copper Tubing (12-31-2003)
FIRE HYDRANT AND FIRE SERVICE DETAILS
WF-01
150mm (6") Fire Hydrant Installation (12-16-2019)
WF-02
150mm (6") Fire Hydrant Installation with Break–Off Check Valve (01-26-2022)
WF-03
High Pressure Dry Barrel Fire Hydrant Installation (10-28-2016)
WF-04
Fire Hydrant Locations and Port Orientation (09-12-2008)
WF-05
100mm (4") and Larger Fire Service Installation (09-11-2017)
GENERAL WATER INFORMATION DETAILS
WI-01
Water, Recycled Water and Sewer Main Parallel Separations (03-01-2001)
WI-02
Water, Recycled Water and Sewer Main Perpendicular Separations (12-31-2003)
WI-03
Water, Recycled Water and Sewer Main Parallel and Perpendicular Separation Notes (11-23-2011)
WI-04
Post Meter Constant Pressure Recycled Water Line 75mm (3") Diameter or Less Crossing Potable Water Main or Lateral within Public Right-of-Way (03-01-2001)
WI-05
Not Used
WI-06
Standard Symbols for Potable and Recycled Water Construction Drawings (11-03-2006)
MISCELLANEOUS WATER DETAILS
WM-01
Water Test Station Installation (11-03-2006)
WM-02
Water Test Station Enclosure Locations (11-03-2006)
WM-03
Retaining Wall for Fire Hydrants and Water and Recycled Water Appurtenances (09-12-2008)
WM-04
Protection Post Installation (12-31-2004)
WM-05
Demountable Protection Post Installation (12-31-2004)
WM-06
Easement/Utility Marker Post Installation (12-31-2004)
WM-07
Replacement of Sewer Lateral Crossings (03-01-2001)
WM-08
Recycled Water "Do Not Drink" Sign (11-16-2007)
PIPELINE DETAILS
WP-01
Warning/Identification Tape and Tracer Wire Installations (12-31-2004)
WP-02
Pipe Bedding and Trench Backfill for Potable and Recycled Water Mains (08-03-2018)
WP-03
Cutting and Plugging Abandoned Water, Recycled Water and Sewer Mains (03-01-2001)
WP-04
Pipe Casing Installation (03-01-2001)
WP-05
Slope Protection Installations (07-30-2007)
WP-06
Pipe Protection Pad Installations (03-01-2001)
WP-07
Cut - Off Wall Installation in Traveled Areas style (03-01-2001)
WP-08
Pipe Encasement for Existing Water Main at Utility Undercuts (09-03-2001)
WP-09
Pipe Support for Undercut Sewer Mains (11-01-2002)
BACKFLOW PREVENTION DETAILS
WR-01
19mm through 50mm (3/4” through 2”) Reduced Pressure Backflow Prevention Device (11-12-2020)
WR-02
75mm (3") and Larger Reduced Pressure Backflow Prevention Device (11-23-2011)
WR-03
25mm and 50mm (1" and 2") Recycled Water Irrigation Check Valve Installation (01-26-2022)
WR-04
Recycled Water Irrigation Cross Connection Test Station (01-26-2022)
WR-05
Temporary Potable Water to Recycled Water Inter-Connection (03-01-2001)
WR-06
75mm (3") or Larger Recycled Water Irrigation Wye Strainer & Check Valve Installation (09-12-2008)
WR-07
75mm (3") or Larger Recycled Water Irrigation Cross Connection Test Station (09-12-2008)
WR-08
25mm and 50mm (1" & 2") Recycled Water Irrigation Reduced Pressure Backflow Device Installation (08-03-2018)
WATER SERVICE LATERAL DETAILS
WS-01
25mm (1") Water Service Installation (07-28-2014)
WS-02
50mm (2") Water Service Installation style (12-31-2003)
WS-03
Meter Box Locations for Water and Recycled Water Appurtenances (12-31-2003)
WS-04A
75mm (3"), 100mm (4") or 150mm (6") Above Grade Meter Installation
(02-11-2020)
WS-04B
75mm (3"), 100mm (4") or 150mm (6") Above Grade Meter Installation - Notes
(02-11-2020)
WS-05A
75mm (3"), 100mm (4") or 150mm (6") Meter Installation
(02-11-2020)
WS-05B
75mm (3"), 100mm (4") or 150mm (6") Meter Installation - Notes
(02-11-2020)
WS-06
Vault Locations for 100mm (4") and Larger Water Services (03-01-2001)
WS-07
Existing Water Service Assembly Reconnection (03-01-2001)
WS-08
Existing Water Service Abandonment (11-12-2020)
WS-09
25mm (1") Duel Domestic/Fire Water Service Installation (11-16-2007)
THRUST AND ANCHOR BLOCKS AND PIPE RESTRAINT DETAILS
WT-01
A
Concrete Thrust and Anchor Block Installations (01-26-2022)
WT-01
B
Concrete Thrust and Anchor Block Installations - Notes (01-26-2022)
WT-01C
Concrete Thrust and Anchor Block Installations (01-26-2022)
WT-02
Valve Support Blocks (11-16-2007)
WT-03A
Restraint Fitting Support Block (11-12-2020)
WT-03B
Restraint Fitting Support Block (Cont) (11-12-2020)
VALVE DETAILS
WV-01
Gate Well Installation, Type 1 for Valves 100mm (4") and Larger (12-31-2003)
WV-02
Gate Well Installation , Type 2 for Valves 100mm (4") and Larger (11-01-2002)
WV-03
Gate Well Identification (11-16-2007)
WV-04
Steel Valve Stem Extension for Valves 100mm (4") and Larger (08-03-2018)
WV-05
Steel Valve Stem Extension for Valves 50mm (2") and Smaller (7-30-2007)